Thông số kỹ thuật

Electric current

Rated current IN
1000 A
Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2
100 kA
Rated ultimate short-circuit breaking capacity Icu under 240 V AC IEC 60947-2
100 kA
Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2
70 kA
Rated ultimate short-circuit breaking capacity Icu under 415 V AC IEC 60947-2
70 kA
Breaking capacity on 1-pole for AC 230 V IEC 60947-2
60 kA
Breaking capacity on 1-pole for AC 400 V IEC 60947-2
9 kA

Architecture

Number of poles
3
Control/operation element
Toggle
Device construction type
Fixed built-in

Capacity

Number of modules
12

Tripping

Response time when opening
10 ms

Settings

Magnetic protection knob setting xIN
2.5, 5, 8
Range of magnetic adjustment
5600 A, 7000 A, 8820 A, 10000 A, 10000 A, 10000 A, 10000 A
Thermal protection knob setting xIN
0.4, 0.5, 0.63, 0.8, 0.9, 0.95, 1
Adjustment range short-term delayed short-circuit release
0 - 0 A

Frequency

Frequency
50 - 60 Hz

Installation, mounting

Nominal tightening torque
65 - 65 Nm
Mounting-/Connection Position
Front

Voltage

Rated impulse withstand voltage Uimp
8000 V
Rated insulation voltage Ui
800 V
Rated operational voltage Ue
220 - 690 V

Functions

Trip unit
LSI

Main electrical attributes

Magnetic protection trip time
100 - 200 ms

Power

Power dissipation at IN
186 W
Power loss per pole at In
62 W

Endurance

Electric endurance in number of cycles
1000
Number of mechanical operations
4000

Equipment

Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0

Safety

Ingress Protection (IP) class
IP4X

Use conditions

Operating temperature
-25 - 70 °C

Connection

Cross-section flexible conductor
2x 240 mm²
Cross-section rigid conductor
2x 240 mm²
Connector/plug type
Terminal

Controls and indicators

Motor drive integrated
No

Compatibility

Suitable for DIN Rail
No

Power supply

Position power supply
Bidirectional